Periodontal probes look almost identical in a catalogue, yet the markings on the tip decide how a clinician reads pocket depth and charts it. Ordering a probe with the wrong marking set means a team works with two systems side by side, or the probe goes back. This guide explains the patterns we make, what the markings mean, and how to name a probe on a quotation.
How probes are named
A probe is identified by three things:
- Pattern or figure: a name or code, such as Williams, Michigan, CP-15 / UNC or CPG 11.5 WHO.
- Marking set: the millimetre points printed or banded on the tip, for example 3-6-8-12.
- Ends: single-ended, or double-ended with a second working end.
Two probes with the same name from different makers can carry different markings, so quote the marking set as well as the name. If you are matching probes you already use, read the markings off the tip and include them on your enquiry.
Williams-type markings: 1-2-3-5-7-8-9-10
This is the most familiar set. The gaps at 4 and 6 make the bands easier to count at a glance. In our range it appears on the Williams Fig. W, the Goldman-Fox, the Meritt A and Meritt E, the Fig. 10 and the Fig. 2GG. For a second working end, see the Williams DE Offset and the Goldman-Fox Williams double-ended probes.
Fewer, wider bands: 3-6-8 and 3-6-8-12
Some clinicians prefer fewer marks, which read quickly during screening. The Michigan probe is marked 3-6-8. The CPG 12, CPNG 12S (with ball) and Mercury add a 12 mm mark (3-6-8-12), while the Fig. 8 and Fig. 11 are marked 3-6-8-11.
Even 2 mm steps, and graduated tips
The CPNG 22 is marked every 2 mm, from 2 to 12. For graduated tips, we make the CP-15 / UNC (single-ended, millimetre-marked) and the CP 12 / Thin Williams (double-ended).
WHO probes with a ball end
The CPG 11.5 WHO has a ball end and markings at 3.5, 5.5, 8.5 and 11.5 mm. UK practices carrying out the Basic Periodontal Examination (BPE) generally use a WHO-type probe, so check which probe your team charts with before ordering in volume.
Furcation and flat probes
Furcation probes have curved working ends for assessing furcation areas. We make graduated Nabers furcation probes and the Fig. 3N Nabers (flat), both double-ended. The UT 34 Calitoni (flat) is another double-ended flat pattern.
Handles and ends
Our single-ended probes use an octagonal handle; our double-ended probes use a knurled handle. Single-ended figures suit quick screening, while double-ended figures put two working ends on one instrument and save space on the tray.
Care and reprocessing
- Clean promptly after use so debris does not dry on the tip or in the markings.
- Wash manually or ultrasonically, rinse and dry fully before sterilising.
- Sterilise in a standard steam autoclave cycle, following your practice’s decontamination protocol.
- Check that the markings are legible and the tip is straight before each use; retire any probe that is bent or worn.
What to put on your quotation
- Pattern or figure, and the marking set, for each line.
- Single-ended or double-ended, and “with ball” where it applies.
- Quantities per line, and whether probes go into examination sets.
- The SKU from our product page, where you have it.
Browse all patterns in explorers and probes and periodontal pocket probes. For a full checklist covering forceps, elevators and other instruments, see what to specify when ordering dental hand instruments.
Balban Industries has made dental and surgical instruments in Sialkot, Pakistan since 1985. Our instruments are CE marked and produced under ISO 9001:2015 and ISO 13485:2016. Request a quotation by SKU, or UK buyers can use the quote form on Supplying the UK.