How to choose Gracey curette figures for a standard tray

Most UK practices, hygienist suites and dental schools keep a small set of Gracey curettes on the periodontal tray, not every figure in the catalogue. The figures look similar until you know that each one is shaped for particular tooth surfaces. Choosing the wrong set means either reaching for the wrong instrument mid-appointment or buying duplicates you do not need. This guide sets out the standard Gracey figure convention so a buyer, practice manager or hygienist can specify a sensible tray.

It is buyer education, not clinical training. Technique, angulation and which edge to use remain the clinician’s responsibility. Manufactured instruments from Balban Industries in Sialkot, Pakistan are CE marked and produced under ISO 9001:2015 and ISO 13485:2016; ask for the figure and SKU that match your current tray list.

What “area-specific” means

A Gracey curette is area-specific: the shank angle and the offset blade are made so that one working edge sits against a particular root surface when the instrument is held correctly. Only that edge is used. Universal curettes (for example a Columbia) have two usable edges and a different shank; sickle scalers are for supragingival calculus and are a different pattern again.

In practice this means you do not buy “a Gracey” — you buy named figures. The standard tray covers every tooth surface with a short list of those figures, then adds a few more only when the practice treats many deep molar pockets.

The core anterior figures

  • Fig. 1/2 — all surfaces of anterior teeth. Often the first Gracey on a student or hygienist tray.
  • Fig. 3/4 — also an anterior figure under the standard convention. Many trays carry 1/2 or 3/4, not both, unless teaching or preference asks for the pair.
  • Fig. 5/6 — anterior teeth and premolars. A common “one instrument covers the front of the mouth” choice.

If you are starting from nothing, Fig. 5/6 plus the posterior set below is a practical minimum. If the practice already works to a teaching list that names 1/2 and 3/4, match that list rather than inventing a new one.

The core posterior figures

  • Fig. 7/8 — buccal and lingual (facial and lingual) surfaces of posterior teeth, premolars and molars.
  • Fig. 11/12 — mesial surfaces of posterior teeth.
  • Fig. 13/14 — distal surfaces of posterior teeth.

Together, 7/8, 11/12 and 13/14 cover the posterior mouth the way 1/2 or 5/6 covers the anterior. Most standard trays stop here for general practice and routine hygiene.

When Fig. 9/10, 15/16 and 17/18 appear

These three are still standard Gracey figures; they are not “specialist only”. They appear when the tray needs finer or longer access on molars:

  • Fig. 9/10 — buccal surfaces of posterior teeth. Some trays use it alongside or instead of relying only on 7/8 for buccal work.
  • Fig. 15/16 — mesial surfaces of molar teeth, typically after 11/12 when a longer shank helps on first and second molars.
  • Fig. 17/18 — distal surfaces of molars, the usual partner to 15/16.

A periodontal or dental-school tray often carries the full set. A small general practice that rarely treats deep molar pockets may never need 15/16 and 17/18. Confirm against the instruments already in use before you add them.

A practical standard tray

One workable UK starter set, under the standard Gracey figure convention, is:

  • Anterior: Fig. 5/6 (or Fig. 1/2 if that is what the practice already teaches)
  • Posterior: Fig. 7/8, Fig. 11/12, Fig. 13/14
  • Optional molars: Fig. 15/16 and Fig. 17/18
  • Optional buccal complement: Fig. 9/10

Put the same set on every surgery’s tray so locums and therapists can find the figure by number. Keep a periodontal probe (CP-15 / UNC) and a sickle scaler Fig. 204 on the same tray for probing and supragingival work; they are not Gracey substitutes.

What to specify when ordering

When you request a quotation, name each figure clearly and include the SKU from the product page or your previous invoice. For Balban Gracey curettes the SKUs run in sequence from 07-1583 (Fig. 1/2) to 07-1591 (Fig. 17/18). Also confirm:

  • Figure — written as Fig. 11/12, not “the mesial one”.
  • Handle — these pages are double-ended with a knurled handle; say if you need a different handle system.
  • Quantity — how many of each figure per surgery, plus spares for sharpening rotation.

There is no public list price on balban.com; use the contact form or the quote form on Supplying the UK. For a wider checklist that covers elevators, forceps and kits as well as curettes, see what to specify when ordering dental hand instruments.

Care, in brief

Clean Gracey blades promptly so calculus does not dry on the cutting edge; wash, rinse, dry, then steam-sterilise under your practice’s decontamination protocol. Inspect and sharpen regularly; retire a curette with a bent shank or a chipped blade. Follow the manufacturer’s instructions for use alongside your own policy.

Where to browse the set

All nine Gracey figures above are live product pages. Browse them under scalers and curettes, and see related periodontal instruments in Periodontia instruments. The parent dental instruments category lists the full range.

When you buy from a Pakistan manufacturer, quality systems matter as much as the figure list. What ISO 13485 means when buying from Pakistan explains why CE marking with ISO 9001:2015 and ISO 13485:2016 is the claims set Balban uses — and the only one used on this site.

Balban Industries · Sialkot, Pakistan · CE marked · ISO 9001:2015 · ISO 13485:2016.

Leave a Reply

Your email address will not be published. Required fields are marked *